358 Fence Posts and Fixings: 8 Connection Details to Specify

Stacked green hollow posts and slotted flat clamp bars

358 fence posts and fixings determine how a mesh panel becomes an installed fence. A panel’s wire size and narrow openings matter, but the post section, connection geometry and fastener arrangement determine whether the delivered parts fit together and match the project design.

This guide uses the supplied catalogue and component photographs to explain the purchasing choices. WIRE MESH DEPOT can quote panels, posts, continuous fixing bars, individual clips, caps and hardware as a coordinated package. Start with the 358 security fence product page, then build a connection schedule for each type of bay.

358 fence posts with full-height fixing bars for embedded installation
Post and bar lengths, hole positions and panel overlap must be coordinated before production.

1. Read the complete post section

The catalogue lists an 80 × 60 × 3 mm rectangular hollow section and an 83 × 64 × 3 mm C-section option. Write all three dimensions in the order. A section name without wall thickness does not define the same quantity of steel or the same structural behaviour.

For a rectangular post, show which face is presented to the fence line and which face receives the fixing. For a C section, show the opening direction and how its lips or returns interact with the connection. Orientation affects both installation and the way loads enter the support.

Post entryInformation to record
SectionProfile, outside dimensions, wall thickness and tolerances
OrientationFace or opening direction relative to the panel
LengthOverall length, installed height and any embedded portion
FabricationHoles, welded plates, extensions and cap arrangement
FinishCoating route and requirements for the completed component
Design referenceApproved structural and installation drawings

The catalogue sections are useful references for discussion, not universal selections for every height or location. Fence height, wind, soil, attachments and the support arrangement need to be assessed together. A taller panel does not become adequately supported merely by ordering a longer version of an otherwise unchanged post.

2. Separate embedded and base-plated details

An embedded post continues below finished ground into the specified foundation. Its order length must reflect that installation. Record the intended ground line on the drawing where it helps prevent confusion between panel height, installed post height and total steel length.

A base-plated post transfers loads through a welded plate and anchors into a designed supporting element. Specify the plate size and thickness, hole pattern, weld detail and orientation. The anchors and concrete must be selected for the project; the plate is not a complete foundation design by itself.

358 fence fixing bar and base-plated post connection detail
The panel connection and base plate are different interfaces, each requiring its own drawing details.

The supplied fabrication photograph shows a galvanized post base and holes. It is useful for understanding the component, but it does not establish anchor capacities, concrete suitability or a universal plate thickness. Those values belong to the approved design.

Keep mounting hardware distinct from panel-fixing hardware in the parts list. A missing anchor assembly and a missing panel bolt stop different stages of installation, and their quantities are not determined in the same way.

3. Choose continuous bars or individual clips

A continuous fixing bar holds the panel edge along a vertical line, using the specified fastening positions. Individual clips hold the mesh at discrete locations. Both can be legitimate connection formats when matched to the panel, post and required performance.

Specify the bar width, thickness, length, hole positions and contact detail. Where two panels meet at a line post, the drawing should show whether they overlap or sit side by side and how the bar engages them. Do not assume every full-height bar uses the same overlap.

For individual clips, specify the profile, material, thickness, quantity and vertical positions. The clip must engage the intended wires and seat against the selected post. A clip that looks similar in a photograph may have a different throat or bolt offset and may not fit the supplied panel.

Four illustrated 358 fence clip and continuous fixing-bar arrangements
Connection illustrations help select a format; dimensions and component quantities still need an approved detail.
Connection choiceKey purchase checks
Continuous barLength, section, hole pitch, panel contact, overlap and edge clearance
Claw or formed clipProfile fit, mesh engagement, bolt position and number per post
Corner connectionReturn angle, post faces, independent fixing access and panel offsets
Wall connectionPlate arrangement, supporting wall suitability and specified anchorage

For bent panels, check where the bends meet the post and whether clamps land on straight wire sections or a defined profile. Trial assembly is often the fastest way to expose a mismatch before thousands of components are packed.

4. Define the complete fastener assembly

List the bolt, nut, washers and any special component as an assembly. Include diameter, length, material or grade, protective finish and installation requirements. The bolt must suit the combined thickness of the post connection, panel and clamp rather than only the nominal hole size.

The supplied close-up shows a nut and bolt arrangement described as tamper resistant. Its final behaviour depends on the selected hardware and completed installation. A photograph of a hexagonal driving feature still present does not prove that a specified breakaway or other final anti-tamper operation has been completed.

Ask how the selected assembly is tightened, checked and later serviced. Some projects need controlled maintenance access; others prioritize restricted external access. Resolve that operational choice before ordering a special fastener that the site team cannot install or remove as intended.

Record tightening requirements from the approved fastener and connection specification. Do not assign a generic torque from a product photograph. Coatings, lubrication, bolt grade and assembly geometry can affect the required procedure.

5. Include caps and coating compatibility

The catalogue offers plastic and metal post caps. Specify the cap type, fit, colour and retention arrangement. The cap must match the delivered section, including the relevant dimensions and coating build, rather than a nominally similar tube.

Review how the post is fabricated and coated before the cap is fitted. Galvanizing and drainage features should remain consistent with the fabrication design. Do not improvise sealing or drilling at site without checking the effect on the component and coating.

Fixing bars, clips and fasteners need a compatible protection specification as well as the posts. A powder-coated panel connected with unsuitable hardware can develop local appearance or corrosion problems. Our coatings guide explains why the finish should be written for the whole system.

6. Schedule corners, ends and gate interfaces

A straight run does not describe the entire fence. End posts, corners, changes of direction and gate interfaces need their own details and quantities. A corner may need a different post orientation or extra connection parts even when the panel type stays unchanged.

At a gate, distinguish the fence support from the gate support. Hinges, operators and moving leaves introduce requirements that a standard intermediate post may not satisfy. Coordinate the adjacent panel connection with the gate frame and clear opening.

For wall returns, removable bays or transitions to another fence type, show the complete interface. An installer should not have to invent a bracket because the last panel reaches an unexpected wall surface. Use item codes for these special parts and identify them on the packing list.

7. Calculate quantities from the actual layout

For an isolated straight run of N bays, a common starting count is N + 1 posts. It is only a counting example: shared corners, separate runs, gates and changes of post type alter the final schedule. Count the actual layout rather than applying one formula to the total perimeter.

Similarly, “four clips per post” is incomplete unless the connection drawing confirms what each clip holds and which posts receive that arrangement. A shared line post, an end post and a corner can use different quantities. Build the bill of materials from connection types, then reconcile it with the number of bays.

ASTM F3204 addresses design and construction of welded-wire security fence systems. It is a useful reference for treating supports and connections as part of the complete barrier rather than selecting mesh alone.

8. Approve a connection sample before packing

Ask for a representative assembled bay or clearly documented trial fit. Confirm panel orientation, post spacing, bar or clip contact, hole alignment and tool access. Include a corner arrangement when it differs from the straight run.

After approval, record the assembly revision and keep the component codes consistent through production, inspection and packaging. Label hardware packs by type and intended use. Include an agreed spare quantity so the installer does not substitute unapproved parts when a small component is lost.

The installation guide covers setting out and site checks. The quality inspection guide explains how to verify post dimensions and the connection before release.

358 fence posts and fixings questions

Are 80 × 60 × 3 mm posts suitable for every 358 fence?

No. That is a catalogue reference. The selected post and support design must match the project height, loading and installation conditions.

Are continuous bars always better than clips?

Selection depends on the approved system and project requirements. Compare the complete connection, including contact, fastening positions and installation access.

Can the installer choose bolts after delivery?

The bolt assembly should be specified with the connection. Late substitution can affect fit, corrosion protection and the intended tamper resistance.

Should caps and spare fixings be included in the quotation?

Yes. List them explicitly so a panel-and-post quote is not mistaken for a complete installation package.

Send your layout and preferred fixing arrangement for a coordinated panel, post and hardware quotation.

Scroll to Top