358 fence specifications need to describe the actual panel and its connections, not just repeat a familiar product name. A 2.5 m wide panel with a 4.0 mm steel wire, a 2.2 m wide panel with unequal wire diameters, and a bent panel can all appear in a security-mesh enquiry. They will not have the same weight, fixing arrangement or delivered cost.
This guide translates WIRE MESH DEPOT’s supplied catalogue into a practical purchase specification. Use the reference dimensions to start the conversation, then record the selected combination on an approved drawing. For system options and an itemized quotation, see our 358 security fence product page.
On this page

1. Define the 358 mesh measurement
The familiar 358 pattern is associated with nominal 76.2 × 12.7 mm spacing. The long and short directions must be identified on the drawing. Write whether the dimensions are measured between wire centres or between the exposed wire surfaces. These two conventions are different, especially along the narrow side.
For example, if the agreed centre spacing is 76.2 × 12.7 mm and the finished wire diameter is 4.0 mm in both directions, the illustrative clear gaps are 72.2 × 8.7 mm. This is a geometry example, not an additional catalogue size. A coating increases the finished diameter and therefore changes the clear gap slightly.
Specify orientation as well. A photograph rotated by 90 degrees can make the same grid look different, while an intentionally vertical narrow-slot panel is a separate arrangement that should be reviewed with its fixing layout. Never leave orientation to an image filename.
2. Record horizontal and vertical wire separately
The supplied catalogue lists horizontal wire options of 3.0, 3.5 and 4.0 mm, with 4.0 mm vertical wire for its Type A and Type B panels. These are selectable constructions. A buyer requiring 4.0 mm in both directions should state that expressly rather than approving only “358 mesh.”
| Drawing entry | What to record | Why it matters |
|---|---|---|
| Horizontal wire | Chosen diameter and tolerance | The numerous closely spaced wires substantially affect steel quantity |
| Vertical wire | Chosen diameter and tolerance | Defines the other direction of the welded grid |
| Measurement state | Steel core, zinc-coated wire or finished coated wire | Prevents a coating thickness being mistaken for steel |
| Gauge description | Named scale, metric diameter and tolerance | A bare gauge number can be ambiguous |
“8 gauge” is a common trade explanation of the final digit in 358, but it is not a universal substitute for 4.0 mm. SWG and AWG use different conversions. The TR Fastenings gauge tables illustrate that distinction. Put millimetres first in an international purchase order.
At an unchanged grid and panel size, wire cross-sectional area varies with the square of diameter. The ratio 3.5² ÷ 4.0² is about 0.766. That comparison concerns the affected wire direction, not the entire panel or fence system. It explains why two apparently similar quotations can have different mesh weights without providing a valid finished-panel weight on its own.
3. Select panel height and width explicitly
The catalogue offers widths of 2.20 and 2.50 m for its Type A and Type B panels. Its height schedule contains 1800, 2000, 2100, 2200, 2400, 2500 and 3000 mm. These are useful ordering references; availability and the complete support design are checked for the chosen combination.
| Panel height | Type A profile | Type B catalogue bends |
|---|---|---|
| 1800 mm | Flat | 3 |
| 2000 mm | Flat | 3 |
| 2100 mm | Flat | 4 |
| 2200 mm | Flat | 4 |
| 2400 mm | Flat | 4 |
| 2500 mm | Flat | 5 |
| 3000 mm | Flat | 6 |
State whether height refers to the panel body, the installed fence above finished ground, or the total height including toppings. Likewise, panel width is not automatically the post centre distance. An overlapping fixing-bar connection and a panel held between post faces can need different setting-out dimensions.
Include finished dimensional tolerances and the measuring method. A panel measured flat on supports is not necessarily comparable with one measured while lifted or leaning. Identify the reference edges and any protruding wires, and specify how the last bay will be closed.

4. Distinguish flat, bent and alternative meshes
Type A is the flat 358 panel. Type B uses reinforcing bends with the same nominal 76.2 × 12.7 mm mesh reference. The bend depth, direction and positions affect stacking, post clearances and the contact between the panel and clamp. A bend count alone is not a complete profile drawing.
The same catalogue also shows Type C with a 100 × 15 mm pattern, 3.5 mm horizontal wire, 5.5 mm vertical wire, and an additional horizontal-wire arrangement at 180 mm intervals. Type C should be quoted as a separate close-mesh option. Its dimensions should not be silently substituted into a standard 358 order.
If a tender calls for flat panels, seek approval before offering a bent alternative. If a buyer prefers a profiled appearance, confirm that the selected fixing and gate infill work with that profile. Our 358 fence comparison guide explains where mesh geometry and panel profile serve different purposes.
5. Specify posts, fixings and finish together
Catalogue post references include an 80 × 60 × 3 mm rectangular hollow section and an 83 × 64 × 3 mm C section. These are product references, not universal structural selections for every fence height and site. The order must identify the section orientation, wall thickness, length, cap and connection detail.
Post length includes the above-ground portion and, for embedded posts, the portion below ground. A base-plated post needs its plate dimensions, weld detail, hole pattern and anchor arrangement instead. Corner, end and gate posts can differ from intermediate posts. List each type separately so a straight-run quantity is not mistaken for the whole system.

The finish description should identify the zinc route and any organic topcoat. “Galvanized and green” leaves open whether wire was coated before welding or the fabricated assembly was hot-dip galvanized afterwards. It also leaves the topcoat grade, preparation and acceptance requirements unresolved. Use the 358 fence coatings guide to build this section of the specification.
6. Turn the dimensions into a purchasing schedule
A useful schedule lets the factory, inspector and installer refer to the same item numbers. Start with the layout revision and assign each panel and post configuration a code. Quote quantities by code, not only by total metres. Include gate interfaces, changes of level, removable bays and spare components.
| Specification group | Minimum information |
|---|---|
| Panel | Profile, orientation, height, width, grid convention, both wire sizes, tolerances and edge detail |
| Support | Post section, thickness, length, spacing, mounting and structural drawing reference |
| Connection | Clamp or bar geometry, fastening positions, bolt assembly and installation access |
| Finish | Zinc process, coating requirements, pretreatment, powder grade, colour and approved sample |
| Acceptance | Inspection locations, methods, sampling, records and treatment of nonconforming items |
| Delivery | Package quantities, identification, protection, unloading constraints and delivery term |
For example, a buyer can request “Type B, 2500 mm high × 2500 mm wide, five bends, 4.0 mm steel wire in both directions” as the start of an enquiry. It still needs the mesh convention, bend drawing, coating, post design, fixings and quantity before it becomes a complete order. This example illustrates the specification process; it is not a universal recommended fence design.
Use an agreed standard as a framework where the project requires one. EN 10223-7 concerns welded steel fencing panels. Stating the standard number does not replace the selected dimensions or order-specific inspection evidence.
7. Define the documents needed before shipment
Ask for the approved shop drawing, bill of materials, dimensional inspection record, finish records appropriate to the contract, packing list and representative photographs. If weld testing or material certification is required, specify it before production so samples and records can be traced to the shipment.
Resolve drawing changes in writing. Increasing wire diameter can affect weight, bending and clamps; increasing height can affect posts and foundations. A revised panel should trigger a review of connected parts. The 358 fence quality inspection checklist explains how to verify the resulting order.
358 fence specifications: common questions
Is 76.2 × 12.7 mm always the clear opening?
No. Confirm the convention on the drawing. Wire-centre spacing and the gap between wire surfaces give different dimensions.
Can the horizontal wire be thinner than the vertical wire?
The supplied catalogue includes that option. Record both diameters and obtain project approval instead of describing an unequal-wire panel as 4.0 mm throughout.
Does a 2500 mm wide panel require 2500 mm post centres?
Not necessarily. Post centres depend on the panel edge, overlap and fixing arrangement. Set out the fence using the approved installation drawing.
Is 100 × 15 mm another name for standard 358?
No. It is a different mesh option in this catalogue and should have its own specification and quotation line.
Prepare an accurate enquiry: send your drawing, chosen dimensions, site layout and destination through our quotation form. WIRE MESH DEPOT can organize the panel, post and fixing schedule around those requirements.