Double Wire Fence Panels 656 & 868 2D Fencing

FOB reference price USD 22.00

FOB reference only. Confirm the pricing unit, specifications and quantity for an up-to-date quotation.

Double wire fence panels use paired horizontal wires welded to vertical wires to create a flat mesh boundary. Compare 656 and 868 configurations with WIRE MESH DEPOT, then specify the panel size, posts, fixings and finish for your project.

  • 656: two 6 mm horizontal wires with a 5 mm vertical wire.
  • 868: two 8 mm horizontal wires with a 6 mm vertical wire.
  • Request panel-only or itemized system quotations against your drawings.

Request a 656 or 868 fence quotation

Description

Double wire fence panels are flat welded mesh panels with two horizontal wires positioned on opposite sides of the vertical wires. This paired-wire structure creates a rigid infill without the V-shaped bends used in a typical 3D fence panel.

WIRE MESH DEPOT accepts enquiries for 656 and 868 configurations, with panel dimensions, posts, connection details and coating defined by the project specification. Send your fence layout for an itemized comparison of the required components.

Double Wire Fence Panels: Product Overview

Also described as twin wire mesh fencing, this format combines an open mesh appearance with paired horizontal reinforcement. Typical project enquiries include commercial boundaries, industrial premises, school grounds and recreational areas where the specified fence design calls for a flat welded panel.

  • Flat panel format: a straight mesh face without a V-bend profile.
  • Two wire configurations: compare 656 and 868 using the project requirements.
  • Coordinated connections: match the panel edge and thickness to the post fixing system.
  • Clear component schedule: identify panels, posts, caps and hardware separately in the quotation.

Compare our 3D fence panels if your specification uses a bent mesh design. For a different, close-mesh boundary format, see the 358 security fence. These systems have different structures and should be compared against the intended application.

656 vs 868: What Do the Numbers Mean?

For the configurations described here, the three numbers identify one horizontal wire, the vertical wire and the second horizontal wire. They describe nominal wire diameters in millimetres; they do not describe panel height, a security rating or coating thickness.

ConfigurationFirst horizontal wireVertical wireSecond horizontal wire
6566 mm5 mm6 mm
8688 mm6 mm8 mm

656 868 2d fence panel

With comparable steel, aperture and panel dimensions, the larger wires in an 868 panel give a heavier mesh infill. Selecting the assembled fence still requires a review of the posts, fixings, support spacing and site loads. A larger wire diameter does not replace that design work.

When comparing double wire fence panels, confirm the nominal steel wire diameter, permitted tolerance and whether a reported measurement includes the coating. Also check the actual wire configuration: the broader term “2D fence” is not a universal guarantee of 656 or 868 dimensions.

Double Wire Fence Panels Specifications

Use this table as an enquiry schedule. The 656 and 868 wire definitions are shown above; the remaining dimensions and inclusions are set by the approved quotation and drawings.

ItemDetail to specify
Panel constructionFlat welded steel mesh with paired horizontal wires.
Wire configuration656 or 868; confirm nominal base-wire diameters and tolerances.
Mesh geometrySpecify horizontal and vertical pitch and any required clear aperture; these are not interchangeable measurements.
Panel dimensionsWidth and height, stated separately from post spacing and finished fence height.
Panel edgeRequired top and bottom detail, projection and installation orientation.
PostsSection, wall thickness, length, cap and embedment or base-plate arrangement.
ConnectionsClamps or fixing bars, bolt details and quantity at each post.
CoatingSpecified galvanizing route and any additional powder coating.
ColorAgreed color reference and approved finish sample where required.
Supply scopePanel-only or itemized panels, posts, caps and fixings; gates listed separately when requested.

If your specification calls for a 50 × 200 mm mesh, identify which dimension is horizontal and whether the numbers mean wire-centre spacing or clear opening. That distinction affects the actual opening and prevents mismatched comparisons.

Posts, Coatings and Layout

Double wire fence panels need a fixing system that accommodates the paired wires and the selected panel edges. Confirm the clamp or fixing-bar arrangement with the post section rather than choosing hardware only by appearance.

Show corners, ends, gate openings and changes in level on the layout. Plan stepped sections or other approved details where needed. The installer should follow the project foundation and connection design, including any base plates, anchors and required ground clearance.

The finish specification should distinguish between mesh welded from pre-galvanized wire and mesh galvanized after fabrication. Where a powder finish over hot-dip galvanizing is specified, the American Galvanizers Association provides background on duplex coating systems. The quotation must identify the actual process and acceptance requirements for the supplied panels.

Production Sequence and Inspection

A typical production sequence for double wire fence panels is outlined below. The coating route and post fabrication details may change the order of individual operations.

  1. Specification approval: confirm the wire configuration, mesh geometry, panel dimensions, post layout and finish.
  2. Wire preparation: check the specified steel wire and prepare the required straight lengths.
  3. Welding: position the vertical wires between paired horizontal wires and weld the mesh to the approved pattern.
  4. Panel finishing: trim edges and check panel dimensions, diagonals and flatness.
  5. Post fabrication: prepare posts, fixing locations and any approved base-plate assemblies.
  6. Surface treatment: complete the specified galvanizing and coating operations.
  7. Final inspection: check the agreed wire dimensions, weld condition, coating appearance and component quantities.

If the project needs coating measurements, weld testing or third-party inspection, define the sampling plan and acceptance criteria in the order. The 656 or 868 designation alone does not establish those requirements.

Packing and Shipping

Plan double wire fence panels in protected stacks suitable for the panel size, coating and unloading equipment. Specify contact protection at straps and support points so the packing arrangement does not damage the mesh edges or finished surface.

Posts and hardware should be identified separately, with packing marks connected to the component schedule. An export packing list should distinguish panel configuration, dimensions, quantity and package weight so the receiving team can check the shipment efficiently.

For a freight quotation, provide the quantity of each panel size and configuration, the associated post and hardware quantities, and the destination port or address. Confirm the trade term, package dimensions and unloading method before arranging dispatch.

Double Wire Fence Panels FAQ

What is the difference between 656 and 868 fencing?

656 uses two 6 mm horizontal wires with a 5 mm vertical wire. 868 uses two 8 mm horizontal wires with a 6 mm vertical wire. Confirm the steel wire diameter basis and tolerance in the quotation.

Are double wire fence panels the same as 3D panels?

No. These double wire panels are flat and use paired horizontal wires. A typical 3D panel uses V-shaped bends. Choose the structure specified for the project rather than substituting one by name.

Is 868 always the right choice?

No. It uses larger wires than 656, but the project still needs suitable posts, fixings and foundations. Compare the complete system, installation requirements and budget against the intended use.

Can I order panels without posts?

Request a panel-only quotation if that is the required scope. Where existing posts will be used, provide their spacing and connection details so compatibility can be checked before ordering.

Can privacy inserts be added?

Only use an infill confirmed for the mesh and support system. Additional screening changes wind exposure, so the assembled fence needs to be reviewed for that condition. Do not assume inserts for chain link or 3D panels will fit.

Are these panels suitable for ball courts?

Some projects specify twin wire mesh for recreational boundaries. Ball containment, rebound behavior, fence height and impact loads must be assessed for the intended sport; the product name alone is not a sports performance approval.

Does the quotation include a coating certificate or test report?

Only the documentation listed in the offer is included. Send the required standard, inspection scope and document type with the enquiry so the correct requirement can be reviewed before production.

How do I obtain a price and production schedule?

Send the 656 or 868 requirement, panel dimensions, mesh specification, quantity, post and fixing details, finish and destination. Include the layout and any inspection requirements to make the quotation complete.

Request a 656 or 868 Fence Quote

Contact WIRE MESH DEPOT with your drawing and component quantities for a double wire fence panels quotation. Compare the complete supply scope, coating specification, packing and delivery basis before placing the order.

Product enquiries are handled under the WIRE MESH DEPOT brand by HUACAN (Hebei Huacan Import and Export Co., Ltd.).

Request a project quotation · Explore the fence range

Get a Quote for Your Project

Tell us the product specifications, quantity and delivery destination so we can quote for your project.

Please include the size, specifications and estimated quantity, if known.
Scroll to Top